Electrical Interview questions Part 12

Query:Difference between megger test equipment and contact resistance meter test instruments?
Resolution: Megger test equipment used to measure cable electric resistance, conductor continuity, phase identification where as contact resistance meter test instruments used to measure low resistance like relays ,contactors.

Query:When we connect the large capacitor bank in series ?
Resolution :we connect large capacitor bank in series to improve the voltage power supply at the load end in balanced transmission line when there is considerable voltage drop along the balanced transmission line due to high impedance of the line.So in order to bring the voltage at the load terminals within its limits (i.e (+ or - %6 )of the rated high terminal voltage )the large capacitor bank is used in series.

Query:What is electrical diversity factor in electrical installations?
Resolution :Electrical diversity factor is the ratio of the sum of the individual maximum demands of the various subdivisions of a system, or part of a system, to the maximum demand of the whole system, or part of the system, under consideration. Electrical diversity factor is usually more than one.

Query:Why field rheostat is kept in minimum position while armature rheostat at maximum position?
Resolution :In motors at the time of starting the armature resistance is introduced to reduce the high starting current and the field resistance is kept minimum to have high starting
torque.

Query:Why computer humming sound occurred in HT transmission line?
Resolution :This computer humming sound is coming due to ionization (breakdown of air into charged particles) of air around transmission conductor. This effect is called as Corona effect, and it is considered as power loss.

Query:What is rated speed?
Resolution :At the time of motor taking normal current (rated current)the speed of the motor is called rated speed. It is a speed at which any system take small current and give maximum efficiency.

Query:What is different between resistance grounding system and resistance earthing system?
Resolution :Resistance grounding system means connecting the neutral point of the load to the ground to carry the residual current in case of unbalanced conditions through the neutral to the ground whereas resistance earthing system is done in an electric equipment in order to protect he equipment in occurrence of fault in the system.

Query:Why should be the frequency 50 Hz 60Hz only why not others like 45, 95 56 or anything , why should we maintain the frequency constant if so why it is only 50 Hz 60Hz?
Resolution :We can have the frequency at any frequency you like, but than you must also make your own motors,high voltage transformers or any other equipment you want to use.We maintain the frequency at 50hz or 60hz because the world maintains a standard at 50 /60hz and the equipments are are made to operate at these frequency.

Comments

Popular posts from this blog

Transformer multiple choice questions part 1

Hello Engineer's Q.[1] A transformer transforms (a) frequency (b) voltage (c) current (d) voltage and current Ans : D Q.[2] Which of the following is not a basic element of a transformer ? (a) core (b) primary winding (c) secondary winding (d) mutual flux. Ans : D Q.[3] In an ideal transformer, (a) windings have no resistance (b) core has no losses (c) core has infinite permeability (d) all of the above. Ans : D Q.[4] The main purpose of using core in a transformer is to (a) decrease iron losses (b) prevent eddy current loss (c) eliminate magnetic hysteresis (d) decrease reluctance of the common magnetic circuit. Ans :D Q.[5] Transformer cores are laminated in order to (a) simplify its construction (b) minimize eddy current loss (c) reduce cost (d) reduce hysteresis loss. Ans : B Q.[6] A transformer having 1000 primary turns is connected to a 250-V a.c. supply. For a secondary voltage of 400 V, the number of secondary turns should be (a) 1600 (b) 250 (c) 400 (d) 1250 A...

Condition for Maximum Power Developed In Synchronous Motor

The value of δ for which the mechanical power developed is maximum can be obtained as, Note : Thus when R a is negligible, θ = 90 o for maximum power developed. The corresponding torque is called pull out torque. 1.1 The Value of Maximum Power Developed        The value of maximum power developed can be obtained by substituting θ = δ in the equation of P m .        When R a is negligible,     θ = 90 o  and cos (θ) = 0 hence, . . .               R a = Z s cosθ   and X s = Z s sinθ        Substituting   cosθ = R a /Z s in equation (6b) we get,         Solving the above quadratic in E b we get,        As E b is completely dependent on excitation, the equation (8) gives the excitation limits for a...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...