Electric Field and Magnetic Field

When charges are separated, a space is created where forces are exerted on the charges. An electric field is such a space. Depending upon the polarity of the charges, the force is either attractive or repulsive. Therefore, we can say that static charges generate an electric field. An electric field influences the space surrounding it. Electric field strength is determined in terms of the force exerted on charges. A capacitor is a reservoir of charge. The two parallel plates of a capacitor, when connected to a voltage source, establishes an electric field between the plates. The positive terminal, or pole of the voltage source will draw electrons from plate 1 whereas the negative pole will push extra electrons on to plate 2. Voltage across the capacitor will rise. The capacitor gets charged equal to the voltage of the source. The capacitance of a capacitor is a measure of its ability to store charge. The capacitance of a capacitor is increased by the presence of a dielectric material between the two plates of the capacitor.

A current-carrying conductor or a coil produces magnetic field around it. The strength of the magnetic field produced depends on the magnitude of the current flowing through the conductor or the coil. There is presence of magnetic field around permanent magnets as well.
A magnet is a body which attracts iron, nickel, and cobalt. Permanent magnets retain their magnetic properties. Electromagnets are made from coils through which current is allowed to flow. Their magnetic properties will be present as long as current flows through the coil.
The space within which forces are exerted by a magnet is called a magnetic field. It is the area of influence of the magnet.

Comments

Popular posts from this blog

Practical Commutation

The e.m.f. induced in each coil of armature is alternating in nature. If load is connected, the current flowing will also be alternating. But the flow of current in a d.c. generator must be undirectional. This can be achieved by the use of commutator. When the armature conductors are under the influence of one pole they carry current in one direction whereas the current is reversed when the conductors are under the influence of other pole. This reversal of current takes place along the magnetic neutral axis. Fig. 1 Note : The reversal of current is likely to take place in short interval when a coil is short circuited by a brush so that transfer of current from one direction to other is carried out without any sparking. This process is called commutation.        Thus a process by which current in the short circuited coil is reversed while it crosses the MNA is called commutation. The time during which the coil remains short circuited is known as...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...