THEORY OF TRANSFORMER

Figure 1.20 shows the elementary diagram of an ideal transformer with secondary side open circuited. It has no ohmic resistance and leakage reactance. There is no loss in an ideal transformer. In Figure 1.16, alternating voltage (V1) is applied at the primary and hence alternating current flows in the primary. The primary draws the magnetizing current Iμ only because it is purely inductive in nature. Iμ is small in magnitude and lags behind V1 by an angle 90°. The function of Iμ is to magnetize the core, and it produces an alternating flux (Φ), which is proportional to Iμ. The alternating flux (Φ) is linked with both primary and secondary windings and causes self-induced emf (E1) in the primary. This self-induced emf (E1) is equal and opposite to V1 at every instant. This induced emf is known as back emf or counter emf. Due to mutual induction, an emf E2 is produced in the secondary. This emf is known as mutually induced emf. It is anti-phase with V1 and its magnitude is proportional to the rate of flux as well as the number of turns of the secondary windings.
Figure 1.21(a) shows the instantaneous values of applied voltage, induced emfs, flux and magnetizing current by sinusoidal waves, while Figure 1.21(b) shows the vectorial representation of the effective values of the above quantities.
images
Figure 1.20 Elementary Diagram of an Ideal Transformere
images
Figure 1.21 Instantaneous Values and Vectorial Representation

Comments

Popular posts from this blog

Transformer multiple choice questions part 1

Hello Engineer's Q.[1] A transformer transforms (a) frequency (b) voltage (c) current (d) voltage and current Ans : D Q.[2] Which of the following is not a basic element of a transformer ? (a) core (b) primary winding (c) secondary winding (d) mutual flux. Ans : D Q.[3] In an ideal transformer, (a) windings have no resistance (b) core has no losses (c) core has infinite permeability (d) all of the above. Ans : D Q.[4] The main purpose of using core in a transformer is to (a) decrease iron losses (b) prevent eddy current loss (c) eliminate magnetic hysteresis (d) decrease reluctance of the common magnetic circuit. Ans :D Q.[5] Transformer cores are laminated in order to (a) simplify its construction (b) minimize eddy current loss (c) reduce cost (d) reduce hysteresis loss. Ans : B Q.[6] A transformer having 1000 primary turns is connected to a 250-V a.c. supply. For a secondary voltage of 400 V, the number of secondary turns should be (a) 1600 (b) 250 (c) 400 (d) 1250 A...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...