Skip to main content

What is the Smart Grid?

The Smart Grid concept combines a number of technologies, end-user solutions and addresses a number of policy and regulatory drivers. It does not have a single clear definition.
The European Technology Platform [3] defines the Smart Grid as:
A SmartGrid is an electricity network that can intelligently integrate the actions of all users connected to it – generators, consumers and those that do both – in order to efficiently deliver sustainable, economic and secure electricity supplies.
According to the US Department of Energy [7]:
A smart grid uses digital technology to improve reliability, security, and efficiency (both economic and energy) of the electric system from large generation, through the delivery systems to electricity consumers and a growing number of distributed-generation and storage resources.
In Smarter Grids: The Opportunity [4], the Smart Grid is defined as:
A smart grid uses sensing, embedded processing and digital communications to enable the electricity grid to be observable (able to be measured and visualised), controllable (able to manipulated and optimised), automated (able to adapt and self-heal), fully integrated (fully interoperable with existing systems and with the capacity to incorporate a diverse set of energy sources).
The literature [7–10] suggests the following attributes of the Smart Grid:
  1. It enables demand response and demand side management through the integration of smart meters, smart appliances and consumer loads, micro-generation, and electricity storage (electric vehicles) and by providing customers with information related to energy use and prices. It is anticipated that customers will be provided with information and incentives to modify their consumption pattern to overcome some of the constraints in the power system.
  2. It accommodates and facilitates all renewable energy sources, distributed generation, residential micro-generation, and storage options, thus reducing the environmental impact of the whole electricity sector and also provides means of aggregation. It will provide simplified interconnection similar to ‘plug-and-play’.
  3. It optimises and efficiently operates assets by intelligent operation of the delivery system (rerouting power, working autonomously) and pursuing efficient asset management. This includes utilising asserts depending on what is needed and when it is needed.
  4. It assures and improves reliability and the security of supply by being resilient to disturbances, attacks and natural disasters, anticipating and responding to system disturbances (predictive maintenance and self-healing), and strengthening the security of supply through enhanced transfer capabilities.
  5. It maintains the power quality of the electricity supply to cater for sensitive equipment that increases with the digital economy.
  6. It opens access to the markets through increased transmission paths, aggregated supply and demand response initiatives and ancillary service provisions.

Comments

Popular posts from this blog

Practical Commutation

The e.m.f. induced in each coil of armature is alternating in nature. If load is connected, the current flowing will also be alternating. But the flow of current in a d.c. generator must be undirectional. This can be achieved by the use of commutator. When the armature conductors are under the influence of one pole they carry current in one direction whereas the current is reversed when the conductors are under the influence of other pole. This reversal of current takes place along the magnetic neutral axis. Fig. 1 Note : The reversal of current is likely to take place in short interval when a coil is short circuited by a brush so that transfer of current from one direction to other is carried out without any sparking. This process is called commutation.        Thus a process by which current in the short circuited coil is reversed while it crosses the MNA is called commutation. The time during which the coil remains short circuited is known as...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...