Skip to main content

Generation of Alternating EMF's

A voltage can be developed in a coil of wire in one of the three ways:
1. By changing the flux through the coil.
2. By moving the coil through the magnetic field.
3. By altering the direction of the flux with respect to the coil.

The first one is that voltage is said to be induced emf and in accordance with Faraday's law, its magnitude at any instant of time is given by the formula as shown below:

e = N(dΦ/dt) x 10 -8 volts

where N is the number turns in a coil
dΦ/dt = rate at which the flux in maxwells changes through the coil

Please take note that in this method of developing an emf, there is no physical motion of coil or magnet; the current through the exciting coil that is responsible for the magnetism is altered to change the flux through the coil in which the voltage is induced. For the second and third method mentioned above, there is actual physical motion of coil or magnet, and in altered positions of coil or magnet flux through the coil changes. A voltage developed on these ways is called a generated emf and is given by the equation:

e = Blv x 10-8 volts

where B is the flux density in lines per square inch
l is the length of the wire, in., that is moved relative to the flux
v is the velocity of the wire, in.per sec., with respect to the flux

Two-pole single AC Generator
The figure above illustrates an elementary a-c generator. The single turn coil may be moved through the magnetic field created by two magnet poles N and S. As you can see, the ends of the coil are connected to two collectors upon which two stationary brushes rest on it. For the clockwise rotation as shown, the side of the coil on north pole N is moving vertically upward to cut the maximum flux under north pole N, while the other side of the coil on south pole S is moving vertically downward to cut the maximum flux under south pole S. After the coil is rotated one quarter of a revolution to the position as shown below:

Rotated 90 degree
the coil sides have no flux to be cut and no voltage is generated. As the coil proceeds to rotate, the side of the coil on south pole S will cut the maximum flux on north pole N. Then, the side of the coil previously on north pole N will cut the maximum flux on south pole S. With this change in the polarity that are cut by the conductors, reversal in brush potential will occur. There are two important points that would like to emphasize in connection with the rotation of the coil of wire through a fixed magnetic field:

1. The voltage changes from instant to instant.
2. The electrical polarity (+) and minus (-) changes with alternating positions under north and south poles.

In actual, ac generator rotate a set of poles that is placed concentrically within a cylindrical core containing many coils of wires. However, a moving coil inside a pair of stationary poles applies equally well to the rotating poles construction; in both arrangements there is a relative motion of one element with respect to the other.

Comments

Popular posts from this blog

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...

Characteristics of Separately Excited D.C. Generators

The characteristics is separately excited d.c. generator are divided into two types, 1) Magnetization   and         2) Load characteristics. 1.1 Magnetization or Open Circuit Characteristics         The arrangement to obtain this characteristics is shown in the Fig. 1. Fig. 1  Obtaining O.C.C. of separately excited generator        The rheostat as a potential driver is used to control the field current and the flux. It is varied from zero and is measured on ammeter connected.        E o  = (ΦPNZ) / (60A)        As I f is varied, then Φ change and hence induced e.m.f. E o  also varies. It is measured on voltmeter connected across armature. No Load is connected to machine, hence characteristics are also called no load characteristics which is graph of E o  against field current I f as sho...