Induction Motor as a Transformer

We know that, transformer is a device in which two windings are magnetically coupled and when one winding is excited by a.c. supply of certain frequency, the e.m.f. gets induced in the second winding having same frequency as that of supply given to the first winding. The winding to which supply is given is called primary winding while winding in which e.m.f. gets induced is called secondary winding. The induction motor can be regarded as the transformer.
       The difference is that the normal transformer is an alternating flux transformer while induction motor is rotating flux transformer. The normal transformer has no air gap as against this an induction motor has distinct air gap between its stator and rotor.
       In an alternating flux transformer the frequency of induced e.m.f. and current in primary and secondary is always same. However in the induction motor frequency of e.m.f. and current on the stator side remains same but frequency of rotor e.m.f. and current depends on the slip and slip depends on load on the motor. So we have a variable frequency on the rotor side. But it is important to remember that at start when N = 0  the value of slip is unity (s = 1), then frequency of supply to the stator and of induced e.m.f. in the rotor is same. The effect of slip on the rotor parameters is already discussed in the previous section.
        And last difference is that in case of the alternating flux transformer the entire energy present in the secondary circuit, is in the electrical form. As against this, in an induction motor part of its energy in the rotor circuit is in electrical form and the remaining part is converted into mechanical form.
Fig. 1  Induction motor as a transformer

       In general, an induction motor can be treated as a generalised transformer as shown in the Fig. 1. In this, the slip ring induction motor with star connected stator and rotor is shown.
So if            E1 = Stator e.m.f. per phase in volts.
                   E2 = Rotor induced e.m.f. per phase in volts at start when motor is at standstill.
       Then according to general transformer there exists a fixed relation between E1 and E2 called transformer ratio.
...     At start when   N =0 , s =1
and we get,

Key Point : So if stator supply voltage is known and ratio of stator to rotor turns per phase is known then the rotor induced e.m.f. on standstill can be obtained.

Comments

Popular posts from this blog

Transformer multiple choice questions part 1

Hello Engineer's Q.[1] A transformer transforms (a) frequency (b) voltage (c) current (d) voltage and current Ans : D Q.[2] Which of the following is not a basic element of a transformer ? (a) core (b) primary winding (c) secondary winding (d) mutual flux. Ans : D Q.[3] In an ideal transformer, (a) windings have no resistance (b) core has no losses (c) core has infinite permeability (d) all of the above. Ans : D Q.[4] The main purpose of using core in a transformer is to (a) decrease iron losses (b) prevent eddy current loss (c) eliminate magnetic hysteresis (d) decrease reluctance of the common magnetic circuit. Ans :D Q.[5] Transformer cores are laminated in order to (a) simplify its construction (b) minimize eddy current loss (c) reduce cost (d) reduce hysteresis loss. Ans : B Q.[6] A transformer having 1000 primary turns is connected to a 250-V a.c. supply. For a secondary voltage of 400 V, the number of secondary turns should be (a) 1600 (b) 250 (c) 400 (d) 1250 A

Condition for Maximum Power Developed In Synchronous Motor

The value of δ for which the mechanical power developed is maximum can be obtained as, Note : Thus when R a is negligible, θ = 90 o for maximum power developed. The corresponding torque is called pull out torque. 1.1 The Value of Maximum Power Developed        The value of maximum power developed can be obtained by substituting θ = δ in the equation of P m .        When R a is negligible,     θ = 90 o  and cos (θ) = 0 hence, . . .               R a = Z s cosθ   and X s = Z s sinθ        Substituting   cosθ = R a /Z s in equation (6b) we get,         Solving the above quadratic in E b we get,        As E b is completely dependent on excitation, the equation (8) gives the excitation limits for any load for a synchronous motor. If the excitation exceeds this limit, the motor falls out of step. 1.2 Condition for Excitation When Motor Develops ( P m ) R max        Let us find excitation condition for maximum power developed. The excitation

Electrical Engineering interview questions and answers Part 17

Why star delta starter is preferred with induction motor? Star delta starter is preferred with induction motor due to following reasons: • Starting current is reduced 3-4 times of the direct current due to which voltage drops and hence it causes less losses. • Star delta starter circuit comes in circuit first during starting of motor, which reduces voltage 3 times, that is why current also reduces up to 3 times and hence less motor burning is caused. • In addition, starting torque is increased and it prevents the damage of motor winding. State the difference between generator and alternator Generator and alternator are two devices, which converts mechanical energy into electrical energy. Both have the same principle of electromagnetic induction, the only difference is that their construction. Generator persists stationary magnetic field and rotating conductor