Skip to main content

Basic Principle of Interferometer

Basic Principle of Interferometer

Interferometer is a precise instrument for flow visualization. The variation of refractive index of the flowing gas with density is the basic principle used in thses system. The principle of interference of light waves is used. At a phase angle, the number of fringes are in relation to change in density with respect to the zero fringe condition.

Description of Interferometer

The arrangement consists of the following:
  1. Two windows to form a test section
  2. A light source
  3. Two Lenses L1 and L2
  4. Two beam splitters B1 and B2
  5. Two mirrors M1 and M2
  6. A display Screen.

Operation of Interferometer

  1. Light rays from a source are collimated with a lens L1. That is, the light rays become a parallel beam of rays when they come out of the lens L1.
  2. This collimated light rays are then split by a beam splitter B1. The two beams traverse at right angles to each other.
  3. That is the beam splitter B1 makes half of the light to go to mirrir M1. The remaining half is reflected towards mirror M2.
  4. Beam 1 is made to pass through the test section (to experience the flow filed) and beam 2 travels an alternate path, but of equal length.
  5. The two beams are agin brought together with the help of beam splitter S2 and are then focused onto the display screen.
  6. Because of the variation in the refractive properties of the flowing gas in the test section, beams-1 will have a travel path of different optical length when compared to that of beam 2. Beacuase of this, the two beams will be out of phase and will interface when they are joined together at B2. This causes alternate bright and dark regions called fringes on the display screen.
  7. The number of fringes will be a function of the difference in the optical length of the two beams. That is, for a difference in the path lengths of one wavelength, one fringe will appear. For a difference in the path lengths teo wave lengths, two fringes will appear and so on.
  8. It is to be noted that if medium I the test section has the same optical properties as that of the medium experience by beam 2, no fringe shifts will appear.
  9. Thus by observing ( and photographing) the interference effects, direct measurement of density variations of the flow in the test section can be obtained/ visualized.
  10. The only disadvantage in yusing this instrument is that it is difficult to align the setup to get beams that have travel paths of the same optical lengths.

Comments

Popular posts from this blog

Practical Commutation

The e.m.f. induced in each coil of armature is alternating in nature. If load is connected, the current flowing will also be alternating. But the flow of current in a d.c. generator must be undirectional. This can be achieved by the use of commutator. When the armature conductors are under the influence of one pole they carry current in one direction whereas the current is reversed when the conductors are under the influence of other pole. This reversal of current takes place along the magnetic neutral axis. Fig. 1 Note : The reversal of current is likely to take place in short interval when a coil is short circuited by a brush so that transfer of current from one direction to other is carried out without any sparking. This process is called commutation.        Thus a process by which current in the short circuited coil is reversed while it crosses the MNA is called commutation. The time during which the coil remains short circuited is known as...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...