Types of Armature Winding IN DC Generator

We have seen that there are number of armature conductors, which are connected in specific manner as per the requirements, which is called armature winding. According to the way of connecting the conductors, armature winding has basically two types namely,
a) Lap winding          b) Wave winding
1.1 Lap winding
       In this case, if connection is started from conductor in slot 1 then connections overlap each other as winding proceeds, till starting point is reached again.
       Developed view of part of the armature winding in lap fashion shown in the Fig. 1.
Fig. 1 Lap Winding
       As seen from the Fig. 1, there is overlapping of coils while proceeding.
Note : Due to such connection, the total number of conductors get divided into 'P' number of parallel paths, where P = number of pole sin the machine.
       Large number of parallel paths indicate high current capacity machine hence lap winding is preferred for high current rating generators.
1.2 Wave Winding
       In this type of connection, winding always travels ahead avoiding overlapping. It travel like a progressive wave hence called wave winding. To get an idea of wave winding a part of armature winding in wave fashion is shown in the Fig. 2.
Fig. 2 Wave winding
       Both coils starting from slot 1 and slot 2 are progressing in wave fashion.
Note : Due to this type of connection, the total number of conductors get divided into two number of parallel paths always, irrespective of number of poles of the machine. As number of parallel paths are less, it is preferrable for low current, high voltage capacity generators.
       The number of parallel paths in which armature conductors are divided due to lap or wave fashion of connection is denoted as A. So A = P for lap connection and A = 2 for wave connection.
1.3 Comparison of Lap and Wave Type Winding
 

Comments

  1. Thank you for offering such practical advice on choosing the right low voltage electrician. The emphasis on thorough research, checking credentials, and obtaining multiple quotes ensures I'll make an informed decision. Excited to find the perfect professional for my electrical needs!

    ReplyDelete

Post a Comment

Comment Policy
We’re eager to see your comment. However, Please Keep in mind that all comments are moderated manually by our human reviewers according to our comment policy, and all the links are nofollow. Using Keywords in the name field area is forbidden. Let’s enjoy a personal and evocative conversation.

Popular posts from this blog

Practical Commutation

The e.m.f. induced in each coil of armature is alternating in nature. If load is connected, the current flowing will also be alternating. But the flow of current in a d.c. generator must be undirectional. This can be achieved by the use of commutator. When the armature conductors are under the influence of one pole they carry current in one direction whereas the current is reversed when the conductors are under the influence of other pole. This reversal of current takes place along the magnetic neutral axis. Fig. 1 Note : The reversal of current is likely to take place in short interval when a coil is short circuited by a brush so that transfer of current from one direction to other is carried out without any sparking. This process is called commutation.        Thus a process by which current in the short circuited coil is reversed while it crosses the MNA is called commutation. The time during which the coil remains short circuited is known as...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Winding Pitches

Now we will consider the definitions of different types of winding pitches, required in the design of the armature winding. 1.1 Back Pitch         The distance which is measured interns of armature conductors i.e. between top and bottom coil sides of a coil measured around the back of the armature i.e. away from the commutator is called back pitch and is denoted by . It is measured interms of coil sides. Note : Since it is difference between odd and even number, it is always odd number.        The size of the coil is decided by the back pitch. The back pitch is normally equal to coilsides per pole. It is shown for lap and wave type of winding in the Fig. 1. Fig. 1        The back pitch for the winding shown in the Fig. 1 is y b = 14 - 1 = 13 as coilsides 1and 14 are of coil number 1. 1.2 Front Pitch        It is defined as the distance measured between two c...