Electrical Interview questions Part 10

Q:How do you select a cable size (Cu & Al) for a particular load?
A:At first calculate the electrical current of the load, after that derate the electrical current considering derating factor(depending on site condition and laying of cable) after choose the cable size from cable catalog considering derating electrical current.After that measure the length of cable required from supply point of load to load poin. Calculate the voltage drop which will max 3% (resistance and reactance of cable found from cable catalog of selecting cable) if voltage drop>3%
then choose next higher size of cable.

Q:What are HRC fuses and where it is used?
A:HRC stand for "high rupturing capacity" fuse and it is used in distribution system for electrical transformers.

Q:Which power plant has high load factor?
A:All base load power plants have a high load factor. If we use high efficiency power plants to supply the base load,we can reduce the cost of generation.Hydel power plants have a higher efficiency than thermal & nuclear power plants.

Q:Mention the methods for starting an induction motor?
A:The different methods of starting an induction motor
DOL:direct online starter
Star delta starter
Auto transformer starter
Resistance starter
Series reactor starter

Q:What is the difference between earth resistance and earth electrode resistance?
A:Only one of the terminals is evident in the earth resistance. In order to find the second terminal we should recourse to its definition: Earth Resistance is the resistance existing between the electrically accessible part of a buried electrode and another point of the earth, which is far away.
The resistance of the electrode has the following components:
(A) the resistance of the metal and that of the connection to it.
(B) the contact resistance of the surrounding earth to the electrode.

Q:What is use of lockout relay in ht voltage?
A:A lock-out relay is generally placed in line before or after the e-stop switch so the power can be shut off at one central location. This relay is powered by the same electrical source as the control power and is operated by a key lock switch. The relay itself may have up to 24 contact points within the unit itself. This allows the control power for multiple machines to be locked out by the turn of a single key switch.

Q:What is the power factor of an alternator at no load?
A:At no load Synchronous Impedance of the alternator is responsible for creating angle difference. So it should be zero lagging like inductor.
Query:How to determine capacitor tolerance codes?
Resolution:In electronic circuits, the capacitor tolerance can be determined by a code that appears on the casing. The code is a letter that often follows a three-digit number (such as 130Z).The first two are the 1st and 2nd significant digits and the third is a multiplier code. Most of the time the last digit tells you how many zeros to write after the first two digits and these are read as Pico-Farads.


Query:Why most of analog o/p devices having o/p range 4 to 20 mA and not 0 to 20 mA?
Resolution:4-20 mA is a standard range used to indicate measured values for any process. The reason that 4ma is chosen instead of 0 mA is for fail safe operation .For example- a pressure instrument gives output 4mA to indicate 0 psi, up to 20 mA to indicate 100 psi, or full scale. Due to any problem in instrument (i.e) broken wire, its output reduces to 0 mA. So if range is 0-20 mA then we can differentiate whether it is due to broken wire or due to 0 psi.

Query:Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?
Resolution:Since two bulbs are in series they will get equal amount of  electrical current but as the supply voltage is constant across the bulb(P=V^2/R).So the resistance of 40W bulb is greater and voltage across 40W is more (V=IR) so 40W bulb will glow brighter.
 
Query:What is meant by knee point voltage?
Resolution:Knee point voltage is calculated for electrical Current transformers and is very important factor to choose a CT. It is the voltage at which a CT gets saturated.(CT-current transformer).
 
Query:What is reverse power relay?
Resolution:Reverse Power flow relay are used in generating stations's protection. A generating stations is supposed to fed power to the grid and in case generating units are off,there is no generation in the plant then plant may take power from grid. To stop the flow of power from grid to generator we use reverse power relay.

Query:What will happen if DC supply is given on the primary of a transformer?
Resolution:Mainly transformer has high inductance and low resistance.In case of DC supply there is no inductance ,only resistance will act in the
-->electrical circuit. So high  electrical current will flow through primary side of the transformer.So for this reason coil and insulation will burn out.

Query:What is the difference between isolators and  -->electrical circuit breakers? What is bus-bar?
Resolution:Isolators are mainly for switching purpose under normal conditions but they cannot operate in fault conditions .Actually they used for isolating the CBs for maintenance. Whereas CB gets activated under fault conditions according to the fault detected.Bus bar is nothing but a junction where the power is getting distributed for independent loads.


Query:What are the advantage of free wheeling diode in a Full Wave rectifier?
Resolution:It reduces the harmonics and it also reduces sparking and arching across the mechanical switch so that it reduces the voltage spike seen in a inductive load
 

Comments

  1. The information you've provided is useful because it provides a wealth of knowledge that will be highly beneficial to me. Thank you for sharing that. Keep up the good work

    Cable size calculator australia

    ReplyDelete

Post a Comment

Comment Policy
We’re eager to see your comment. However, Please Keep in mind that all comments are moderated manually by our human reviewers according to our comment policy, and all the links are nofollow. Using Keywords in the name field area is forbidden. Let’s enjoy a personal and evocative conversation.

Popular posts from this blog

Transformer multiple choice questions part 1

Hello Engineer's Q.[1] A transformer transforms (a) frequency (b) voltage (c) current (d) voltage and current Ans : D Q.[2] Which of the following is not a basic element of a transformer ? (a) core (b) primary winding (c) secondary winding (d) mutual flux. Ans : D Q.[3] In an ideal transformer, (a) windings have no resistance (b) core has no losses (c) core has infinite permeability (d) all of the above. Ans : D Q.[4] The main purpose of using core in a transformer is to (a) decrease iron losses (b) prevent eddy current loss (c) eliminate magnetic hysteresis (d) decrease reluctance of the common magnetic circuit. Ans :D Q.[5] Transformer cores are laminated in order to (a) simplify its construction (b) minimize eddy current loss (c) reduce cost (d) reduce hysteresis loss. Ans : B Q.[6] A transformer having 1000 primary turns is connected to a 250-V a.c. supply. For a secondary voltage of 400 V, the number of secondary turns should be (a) 1600 (b) 250 (c) 400 (d) 1250 A

Condition for Maximum Power Developed In Synchronous Motor

The value of δ for which the mechanical power developed is maximum can be obtained as, Note : Thus when R a is negligible, θ = 90 o for maximum power developed. The corresponding torque is called pull out torque. 1.1 The Value of Maximum Power Developed        The value of maximum power developed can be obtained by substituting θ = δ in the equation of P m .        When R a is negligible,     θ = 90 o  and cos (θ) = 0 hence, . . .               R a = Z s cosθ   and X s = Z s sinθ        Substituting   cosθ = R a /Z s in equation (6b) we get,         Solving the above quadratic in E b we get,        As E b is completely dependent on excitation, the equation (8) gives the excitation limits for any load for a synchronous motor. If the excitation exceeds this limit, the motor falls out of step. 1.2 Condition for Excitation When Motor Develops ( P m ) R max        Let us find excitation condition for maximum power developed. The excitation

Effect of Slip on Rotor Parameters : Part2

Effect of Slip on Rotor Parameters 2. Effect of Slip on Magnitude of Rotor Induced E.M.F        We have seen that when rotor is standstill, s  = 1, relative speed is maximum and maximum e.m.f. gets induced in the rotor. Let this e.m.f. be,                 E 2 = Rotor induced e.m.f. per phase on standstill condition         As rotor gains speed, the relative speed between rotor and rotating magnetic field decreases and hence induced e.m.f. in rotor also decreases as it is proportional to the relative speed N s - N. Let this e.m.f. be,                E 2r = Rotor induced e.m.f. per phase in running condition  Now        E 2r α N s while E 2r α N s - N        Dividing the two proportionality equations,               E 2r /E 2 = ( N s - N)/N s    but (N s - N)/N = slip s               E 2r /E 2 = s               E 2r = s E 2        The magnitude of the induced e.m.f in the rotor also reduces by slip times the