Ratings of a D.C. Motor

To change the speed as per the requirements, it is not possible to increase the voltage or currents beyond certain limit. These limits are called ratings of the motor.
       The maximum voltage that can be applied to the motor, safely is called rated voltage or normal voltage of the motor. While changing the applied voltage, one should not apply the voltage more than the rated voltage of the motor.
       Similarly maximum current that field winding can carry, safely is called rated field current of the notor. Hence while changing the flux, one should not increase field current beyond its rated value. This is important rating as far as shunt motor is concerned. In a series motor, the entire armature current flows through the series field winding. The armature current is decided by the load and it can not be changed by changing the resistance of the armature circuit. So the maximum current that armature winding can carry safely is decided by the load called full load current or full load rating of the motor. Motor should not be loaded more than its full load capacity indicated by its full load armature current.
       Exceeding the rating is dangerous from the motor point of view as due to high currents, the heat produced, which is proportional to the square of the current is very large. This may damage the windings electrically.
       Now    N   α    V/Φ
       So for V =  Vrated  and Φ  α  If   rated i.e. when there is no external resistance in the armature and field circuit and motor is excited by normal rated voltage, the speed obtained is called rated speed or normal speed.
...      Vrated    α   Vrated/ If rated 
Note : Note that the rated or normal speed is not the maximum speed with which motor can run safely but it is the speed when the electrical parameters controlling the speed are at their rated values.
        Practically a motor speed can be increased to approximately twice its normal speed safely.
       Thus while controlling the speed, the voltage applied should not be more than rated voltage of a motor, the field current should not be more than its rated value and the current carried by armature should not be more than its full load value. All the ratings are provided by the manufacturer in the form of name plate of a d.c. motor.

Comments

Popular posts from this blog

Transformer multiple choice questions part 1

Hello Engineer's Q.[1] A transformer transforms (a) frequency (b) voltage (c) current (d) voltage and current Ans : D Q.[2] Which of the following is not a basic element of a transformer ? (a) core (b) primary winding (c) secondary winding (d) mutual flux. Ans : D Q.[3] In an ideal transformer, (a) windings have no resistance (b) core has no losses (c) core has infinite permeability (d) all of the above. Ans : D Q.[4] The main purpose of using core in a transformer is to (a) decrease iron losses (b) prevent eddy current loss (c) eliminate magnetic hysteresis (d) decrease reluctance of the common magnetic circuit. Ans :D Q.[5] Transformer cores are laminated in order to (a) simplify its construction (b) minimize eddy current loss (c) reduce cost (d) reduce hysteresis loss. Ans : B Q.[6] A transformer having 1000 primary turns is connected to a 250-V a.c. supply. For a secondary voltage of 400 V, the number of secondary turns should be (a) 1600 (b) 250 (c) 400 (d) 1250 A...

Condition for Maximum Power Developed In Synchronous Motor

The value of δ for which the mechanical power developed is maximum can be obtained as, Note : Thus when R a is negligible, θ = 90 o for maximum power developed. The corresponding torque is called pull out torque. 1.1 The Value of Maximum Power Developed        The value of maximum power developed can be obtained by substituting θ = δ in the equation of P m .        When R a is negligible,     θ = 90 o  and cos (θ) = 0 hence, . . .               R a = Z s cosθ   and X s = Z s sinθ        Substituting   cosθ = R a /Z s in equation (6b) we get,         Solving the above quadratic in E b we get,        As E b is completely dependent on excitation, the equation (8) gives the excitation limits for a...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...