D.C Motor Interview Questions

Q. What is the principle of operation of a D.C Motor?

A. The operation of a D.C Motor based on the principle that when a current carrying conductor is placed in a magnetic field, the conductor experiences a mechanical force. Basically, there is no constructional difference between a d.c. motor and a d.c generator. The same d.c. machine can be run as a generator or motor.

Q. What is back e.m.f or counter e.m.f?

A. When the armature of a d.c. motor rotates under the influence of the driving torque, the armature conductors move through the magnetic field and hence e.m.f. is induced in them as in a generator. The induced e.m.f. acts in opposite direction to the applied voltage V (Lenz’s law) and in known as back or counter e.m.f Eb. It is always less than the applied voltage V, although this difference is small when the motor is running under normal conditions.

Q. What is speed regulation?

A. Speed regulation is the change in speed when the load on the motor is reduced from rated value to zero. It is expressed as a percentage of rated load speed.

Q. Why series motor cannot be started on no-load?

A. Series motor cannot be started without load because of high starting torque. Series motor are used in Trains, Crane etc.

Q: Which type of motor is used in trains, what is the rating of supply used?

A. Dc series is in the used in trains to get high starting torque while starting of the trains and the operating voltage is 1500v dc.

Q. Explain different methods of speed control of d.c shunt motors?

A. Speed control of a d.c shunt motor can be done using
    1. Flux control method ()
    2. Armature control method
3. Voltage control method   

Q. Explain different methods of speed control of d.c series motors?

A. Speed control of a d.c series motor can be done using
    1. flux control method
    2. Armature-resistance control control method

Q. Why is the starting current high in a DC motor (or) Why do we use a starter?

A. For DC motors, Voltage equation is
V=Eb-IaRa
Where V = Terminal voltage,
Eb = Back emf in Motor
Ia = Armature current
Ra = Aramture resistance.
At starting, Eb is zero. Therefore, V=IaRa, Ia = V/Ra, where Ra is very less like 0.01ohm.i.e, Ia will become enormously increased. The excessive current will damage commutator and brushes and eventually blow out the fuses.

Q. How can you reverse the direction of rotation of a D.C Motor?

A. We can reverse the direction of rotation of a D.C Motor by either reversing the field current or armature current. If both the currents are reversed the motor will run in original direction.

Q. Why the field of a D.C Shunt motor should not be open?

A. The shunt motor will achieve dangerously high speed and may destroy itself.

Q. What will happen if the direction of current at the terminals of a D.C Motor is reversed?

A. The direction of rotation of motor remains the same as current in armature and field.

Q. What happens when a D.C motor is connected across an A.C supply?

A. 1. The motor will run but it would not carry same load as it would on d.c supply.
     2. More sparking at the brushes
     3. Eddy currents will be high and will cause overheating and may eventually burn on a.c supply





Q: Mention the methods for starting an induction motor?

A.    1. DOL - direct online starter
2. Star delta starter
3. Auto transformer starter
4. Resistance starter
5. Series reactor starter

Q. What are the types of starters used for starting of D.C Motors?

A. There are two principal types of d.c. motor starters viz., three-point starter and four-point starter. As we shall see, the two types of starters differ only in the manner in which the no-volt release coil is connected.

Q. What are the advantages of star-delta starter with induction motor?

A. The main advantage of using the star delta starter is reduction of current during the starting of the motor. Starting current is reduced to 3-4 times of current of Direct online starting. As the starting current is reduced, the voltage drops during the starting of motor in systems are reduced.

Q. What are the different tests conducted on D.C Machines?

A.    1. Brake test
    2. Swinburne’s test or No-load test
3. Regeneration test or Hopkinson’s test
4. Retardation or Running down test

Q. Why is Swinburne’s test conducted?

A. Swinburne’s test is conducted at No-load condition to predetermine the efficiency at different loads and to measure the losses separately.

Comments

Popular posts from this blog

Transformer multiple choice questions part 1

Hello Engineer's Q.[1] A transformer transforms (a) frequency (b) voltage (c) current (d) voltage and current Ans : D Q.[2] Which of the following is not a basic element of a transformer ? (a) core (b) primary winding (c) secondary winding (d) mutual flux. Ans : D Q.[3] In an ideal transformer, (a) windings have no resistance (b) core has no losses (c) core has infinite permeability (d) all of the above. Ans : D Q.[4] The main purpose of using core in a transformer is to (a) decrease iron losses (b) prevent eddy current loss (c) eliminate magnetic hysteresis (d) decrease reluctance of the common magnetic circuit. Ans :D Q.[5] Transformer cores are laminated in order to (a) simplify its construction (b) minimize eddy current loss (c) reduce cost (d) reduce hysteresis loss. Ans : B Q.[6] A transformer having 1000 primary turns is connected to a 250-V a.c. supply. For a secondary voltage of 400 V, the number of secondary turns should be (a) 1600 (b) 250 (c) 400 (d) 1250 A

Condition for Maximum Power Developed In Synchronous Motor

The value of δ for which the mechanical power developed is maximum can be obtained as, Note : Thus when R a is negligible, θ = 90 o for maximum power developed. The corresponding torque is called pull out torque. 1.1 The Value of Maximum Power Developed        The value of maximum power developed can be obtained by substituting θ = δ in the equation of P m .        When R a is negligible,     θ = 90 o  and cos (θ) = 0 hence, . . .               R a = Z s cosθ   and X s = Z s sinθ        Substituting   cosθ = R a /Z s in equation (6b) we get,         Solving the above quadratic in E b we get,        As E b is completely dependent on excitation, the equation (8) gives the excitation limits for any load for a synchronous motor. If the excitation exceeds this limit, the motor falls out of step. 1.2 Condition for Excitation When Motor Develops ( P m ) R max        Let us find excitation condition for maximum power developed. The excitation

Effect of Slip on Rotor Parameters : Part2

Effect of Slip on Rotor Parameters 2. Effect of Slip on Magnitude of Rotor Induced E.M.F        We have seen that when rotor is standstill, s  = 1, relative speed is maximum and maximum e.m.f. gets induced in the rotor. Let this e.m.f. be,                 E 2 = Rotor induced e.m.f. per phase on standstill condition         As rotor gains speed, the relative speed between rotor and rotating magnetic field decreases and hence induced e.m.f. in rotor also decreases as it is proportional to the relative speed N s - N. Let this e.m.f. be,                E 2r = Rotor induced e.m.f. per phase in running condition  Now        E 2r α N s while E 2r α N s - N        Dividing the two proportionality equations,               E 2r /E 2 = ( N s - N)/N s    but (N s - N)/N = slip s               E 2r /E 2 = s               E 2r = s E 2        The magnitude of the induced e.m.f in the rotor also reduces by slip times the