Action of Commutator

It is seen that, the e.m.f. induced in the conductors is always sinusoidal and commutator converts this sinusoidal e.m.f. to unidirectional e.m.f. Let us see, how it happens.
       For simplicity of understanding the commutator action, consider commutator in its simplest form. Commutator is divided into number of copper segments insulated from each other. In its simplest form, it is assumed to be divided into two segments, each is nothing but the half of the entire commutator drum, separated by insulating material. So in its simplest form it is a  ring with two halves separated by insulation as shown in the Fig. 1.
Fig. 1 Split ring
       Such a ring is called split ring. The brushes P and Q are stationary and pressed on the surface of split ring. Split ring is mounted on the shaft and rotates as armature rotates.
       Consider a single turn generator with conductors (1) and (2). These armature conductors are connected to the two segments of split ring. The external resistance R is connected across brushes P and Q. Under instant 1, the current flowing through resistance R is flowing from left to right as shown in the Fig. 2. This is by assuming the direction of current through conductor (1) downwards which is under N pole and through conductor (2) upwards which is under S pole, at the instant considered. At this instant brush P behaves as positive and Brush Q as negative.
Fig. 2  Action of split ring
       After a next half revolution, we have seen that direction of e.m.f. in the individual conductors reverses. Hence conductor (1) now will carry a current which will be upwards and due to half revolution it will be under S pole. Similarly conductor (2) individually will carry a current downwards now, and will be under N pole as shown in the Fig. 3.
Fig. 3
       Now split ring i.e. commutator is mounted on shaft and rotates with armature. So when conductors will reverse their positions, the split ring sections will also reverse their positions as shown in the Fig. 3.
       But brushes P and Q are stationary and tapping the current from the commutator segments which are in contact with them.
       Hence under instant 2, segment B will be in contact with brush P and segment A will be in contact with brush Q. Due to this, current through resistance R maintains its direction from left to right as shown in the Fig. 3. Brush P remains positive and Q remains as negative.
       The Fig. 4 shows the waveforms of current in the individual conductor and current in external resistance R. Effectively one brush always taps those conductors. carrying a current which is in 180o opposite direction to the conductors under brush one. So one brush remains always positive and other always negative, and the load current is unidirectional.
Fig. 4  Waveforms of current
Note : In the limiting case, number of segments of a commutator is equal to number of armature coils in a practical generator. Due to this, commutating action is very fast and almost straight line i.e. pure d.c. can be obtained across the load.
       In a practical d.c. generator, the small poles in addition to the main poles, fixed to the yoke in between the main poles are used to improve the commutation. These poles are called interpoles.

Comments

Popular posts from this blog

Practical Commutation

The e.m.f. induced in each coil of armature is alternating in nature. If load is connected, the current flowing will also be alternating. But the flow of current in a d.c. generator must be undirectional. This can be achieved by the use of commutator. When the armature conductors are under the influence of one pole they carry current in one direction whereas the current is reversed when the conductors are under the influence of other pole. This reversal of current takes place along the magnetic neutral axis. Fig. 1 Note : The reversal of current is likely to take place in short interval when a coil is short circuited by a brush so that transfer of current from one direction to other is carried out without any sparking. This process is called commutation.        Thus a process by which current in the short circuited coil is reversed while it crosses the MNA is called commutation. The time during which the coil remains short circuited is known as...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Winding Pitches

Now we will consider the definitions of different types of winding pitches, required in the design of the armature winding. 1.1 Back Pitch         The distance which is measured interns of armature conductors i.e. between top and bottom coil sides of a coil measured around the back of the armature i.e. away from the commutator is called back pitch and is denoted by . It is measured interms of coil sides. Note : Since it is difference between odd and even number, it is always odd number.        The size of the coil is decided by the back pitch. The back pitch is normally equal to coilsides per pole. It is shown for lap and wave type of winding in the Fig. 1. Fig. 1        The back pitch for the winding shown in the Fig. 1 is y b = 14 - 1 = 13 as coilsides 1and 14 are of coil number 1. 1.2 Front Pitch        It is defined as the distance measured between two c...