Types of Single Phase Induction Motors

In practice some arrangement is provided in the single phase induction motors so as that the stator flux produced becomes rotating type rather than the alternating type, which rotates in particular direction only. So torque produced due to such rotating magnetic field is unidirectional as there is no oppositely directed torque present. Hence under the influence of rotating magnetic field in one direction, the induction motor becomes self starting. It rotates in same direction as that of rotating magnetic field. Thus depending upon the methods of producing rotating stator magnetic flux, the single phase induction motors are classified as,
  1. Split phase induction motor
  2. Capacitor start induction motor
  3. Capacitor start capacitor run induction motor
  4. Shaded pole induction motor
        To produce rotating magnetic field, it is necessary to have minimum two alternating fluxes having a phase difference between the two. The interaction of such two fluxes produces a resultant flux which is rotating magnetic flux, rotating in space in one particular direction. So an attempt is made in all the single phase induction motors to produce an additional flux other than stator flux, which has a certain phase difference with respect to stator flux.
        Such two fluxes are shown in the Fig. 1 having phase difference of between them.
Fig. 1
       More the phase difference angle α, more is starting torque produced. Thus production of rotating magnetic field at start is important to make the single phase induction motors self starting. Once the motor starts, then another flux Φ2 may be removed and motor can continue to rotate under influence of stator flux or main flux alone.
       Let us see how the rotating magnetic field is produced in various types of single phase induction motors.

Comments

Popular posts from this blog

Transformer multiple choice questions part 1

Hello Engineer's Q.[1] A transformer transforms (a) frequency (b) voltage (c) current (d) voltage and current Ans : D Q.[2] Which of the following is not a basic element of a transformer ? (a) core (b) primary winding (c) secondary winding (d) mutual flux. Ans : D Q.[3] In an ideal transformer, (a) windings have no resistance (b) core has no losses (c) core has infinite permeability (d) all of the above. Ans : D Q.[4] The main purpose of using core in a transformer is to (a) decrease iron losses (b) prevent eddy current loss (c) eliminate magnetic hysteresis (d) decrease reluctance of the common magnetic circuit. Ans :D Q.[5] Transformer cores are laminated in order to (a) simplify its construction (b) minimize eddy current loss (c) reduce cost (d) reduce hysteresis loss. Ans : B Q.[6] A transformer having 1000 primary turns is connected to a 250-V a.c. supply. For a secondary voltage of 400 V, the number of secondary turns should be (a) 1600 (b) 250 (c) 400 (d) 1250 A...

Armature Voltage Control Method or Rheostatic Control of dc motor

Speed Control of D.C. Shunt Motor (Part2)  2. Armature Voltage Control Method or Rheostatic Control        The speed is directly proportional to the voltage applied across the armature. As the supply voltage is normally constant, the voltage across the armature can be controlled by adding a variable resistance in series with the armature as shown in the Fig. 1. Fig. 1 Rheostat control of shunt motor        The field winding is excited by the normal voltage hence I sh is rated and constant in this method. Initially the reheostat position is minimum and rated voltage gets applied across the armature. So speed is also rated. For a given load, armature current is fixed. So when extra resistance is added in the armature circuit, I a remains same and there is voltage drop across the resistance added ( I a R). Hence voltage across the armature decreases, decreasing the speed below normal value. By varyi...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...