Split Phase Induction Motor

This type of motor has single phase stator winding called main winding. In addition to this, stator carries one more winding called auxiliary winding or starting winding. The auxiliary winding carries a series resistance such that its impedance is highly resistive in nature. The main winding is inductive in nature.

                   Let                  Im = Current through main winding 
                   and                  Ist = Current through auxiliary winding

       As main winding is inductive, current Im lags voltage by V by a large angle Φm while Ist is almost in phase in V as auxiliary winding is highly resistive. Thus three exists a phase difference of α between the two currents and hence between the two fluxes produced by the two currents. This is shown in the Fig.1(c). The resultant of these two fluxes is a rotating magnetic field. Due to this, the starting torque, which acts only in one direction is produced.
Fig. 1   Split phase induction motor

       The auxiliary winding has a centrifugal switch in series with it. When motor gather a speed upto 75 to 80% of the synchronous speed, centrifugal switch gets opened mechanically and in running condition auxiliary winding remains out of the circuit. So motor runs only stator winding. So auxiliary winding is designed for short time use while the main winding is designed for continuous use. As the current Im and are splitted from each other by angle 'α ' at start, the motor is commonly called split phase motor.
       The torque-speed characteristics of split phase motors is shown in the Fig.2.
Fig.  2

       The starting torque Tst is proportional to the split angle 'α ' but split phase motors give poor starting torque which is 125 to 150% of full load torque.
        The direction of rotation of this motor can be reversed by reversing the terminals of either main winding or auxiliary winding. This changes the direction of rotating magnetic field which in turn changes the direction of rotation of the motor.

Applications
       These motors have low starting current and moderate starting torque. These are used for easily started loads like fans, blowers, grinders, centrifugal pumps, washing machines, oil burners, office equipments etc. These are available in the range of 1/120 to 1/2 kW.

Comments

Popular posts from this blog

Practical Commutation

The e.m.f. induced in each coil of armature is alternating in nature. If load is connected, the current flowing will also be alternating. But the flow of current in a d.c. generator must be undirectional. This can be achieved by the use of commutator. When the armature conductors are under the influence of one pole they carry current in one direction whereas the current is reversed when the conductors are under the influence of other pole. This reversal of current takes place along the magnetic neutral axis. Fig. 1 Note : The reversal of current is likely to take place in short interval when a coil is short circuited by a brush so that transfer of current from one direction to other is carried out without any sparking. This process is called commutation.        Thus a process by which current in the short circuited coil is reversed while it crosses the MNA is called commutation. The time during which the coil remains short circuited is known as...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Winding Pitches

Now we will consider the definitions of different types of winding pitches, required in the design of the armature winding. 1.1 Back Pitch         The distance which is measured interns of armature conductors i.e. between top and bottom coil sides of a coil measured around the back of the armature i.e. away from the commutator is called back pitch and is denoted by . It is measured interms of coil sides. Note : Since it is difference between odd and even number, it is always odd number.        The size of the coil is decided by the back pitch. The back pitch is normally equal to coilsides per pole. It is shown for lap and wave type of winding in the Fig. 1. Fig. 1        The back pitch for the winding shown in the Fig. 1 is y b = 14 - 1 = 13 as coilsides 1and 14 are of coil number 1. 1.2 Front Pitch        It is defined as the distance measured between two c...