Conducts Tests on Single Phase Induction Motor

Similar to a three phase induction motor, the various tests can be performed on single phase induction motor. The results of these tests can be used to obtain the equivalent circuit parameters of a single phase induction motor.
The tests usually conducted are :

1. No load test or open circuit test
2. Blocked rotor test or short circuit test


1. No load test
       The test is conducted by rotating the motor without load. The input current, voltage and power are measured by connecting the ammeter, voltmeter and wattmeter in the circuit. These readings are denoted as Vo , Io and Wo .
Now                 Wo = Vo Io cosΦ

       The motor speed on no load is almost equal to its synchronous speed hence for practical purposes, the slip can be assumed zero. Hence r2/s becomes ∞ and acts as open circuit in the equivalent circuit. Hence for forward rotor circuit, the branch r2/s + j x2 gets eliminated.
       While for a backward rotor circuit, the term r2/(2 - s) tends to r2/2. Thus xo is much higher then the impedance r2/2 + j x2. Hence it can be assumed that no current can flow through and that branch can be eliminated.
       So circuit reduces to as shown in the Fig.1.
Fig. 1

       Now the voltage across xo is VAB 
But                    VAB = Io xo
...                       xo = VAB /Io
But                   xo = Xo /2
  
       Thus magnetising reactance Xo can be determined.
       The no load power Wo is nothing but the rotational losses.
        

Must Read
  • Why this motor is not self starting
  • Method of starting
2. Blocked Rotor Test
       In balanced rotor test, the rotor is held fixed so that it will not rotate. A reduced voltage is applied to limit the short circuit current. This voltage is adjusted with the help of autotransformer so that the rated current flows through main winding. The input voltage, current and power are measured by connecting voltmeter, ammeter and wattmeter respectively. These readings are denoted as Vsc , Isc and Wsc.
       Now as rotor is blocked, the slip s = 1 hence the magnetising reactance xo is much higher than the rotor impedance and hence it can be neglected as connected in parallel with the rotor. Thus the equivalent circuit for blocked rotor test is as shown in the Fig.2.
Fig. 2

                     Wsc = Vsc Isc cos Φsc
                      cos Φsc =Wsc /Vsc Isc
                                 = blocked rotor power factor
Now               Zeq = Vsc/ Isc
                       Req = Wsc /( Isc)2
But                  Req = R1 + R2
 ...                     R2 = Req - R1
                          = rotor resistance referred to stator
                         Xeq =√(Zeq 2 - Req 2)
                         X1 =  Xwe get,

       The stator resistance is measured by voltmeter-ammeter method, by disconnecting the auxiliary winding and capacitors present if any. Due to skin effect, the a.c. resistance is 1.2 to 1.5 times more than the d.c. resistance.
       Key point : Thus with two tests, all the parameters of single phase induction motor can be obtained.

Comments

Popular posts from this blog

Practical Commutation

The e.m.f. induced in each coil of armature is alternating in nature. If load is connected, the current flowing will also be alternating. But the flow of current in a d.c. generator must be undirectional. This can be achieved by the use of commutator. When the armature conductors are under the influence of one pole they carry current in one direction whereas the current is reversed when the conductors are under the influence of other pole. This reversal of current takes place along the magnetic neutral axis. Fig. 1 Note : The reversal of current is likely to take place in short interval when a coil is short circuited by a brush so that transfer of current from one direction to other is carried out without any sparking. This process is called commutation.        Thus a process by which current in the short circuited coil is reversed while it crosses the MNA is called commutation. The time during which the coil remains short circuited is known as...

Demagnetising and Cross Magnetizing Conductors

The conductors which are responsible for producing demagnetizing and distortion effects are shown in the Fig.1. Fig. 1        The brushes are lying along the new position of MNA which is at angle θ  from GNA. The conductors in the region AOC = BOD = 2θ  at the top and bottom of the armature are carrying current in such a direction as to send the flux in armature from right to left. Thus these conductors are in direct opposition to main field and called demagnetizing armature conductors.         The remaining armature conductors which are lying in the region AOD and BOC carry current in such a direction as to send the flux pointing vertically downwards i.e. at right angles to the main field flux. Hence these conductors are called cross magnetizing armature conductors which will cause distortion in main field flux.        These conductors are shown in the Fig. 2 Fig. 2  ...

Winding Pitches

Now we will consider the definitions of different types of winding pitches, required in the design of the armature winding. 1.1 Back Pitch         The distance which is measured interns of armature conductors i.e. between top and bottom coil sides of a coil measured around the back of the armature i.e. away from the commutator is called back pitch and is denoted by . It is measured interms of coil sides. Note : Since it is difference between odd and even number, it is always odd number.        The size of the coil is decided by the back pitch. The back pitch is normally equal to coilsides per pole. It is shown for lap and wave type of winding in the Fig. 1. Fig. 1        The back pitch for the winding shown in the Fig. 1 is y b = 14 - 1 = 13 as coilsides 1and 14 are of coil number 1. 1.2 Front Pitch        It is defined as the distance measured between two c...